| Generator | ||||
| kVp Range | 40-150 | |||
| mA Range | 10-640 (64kW) 10-800 (80kW) | |||
| High Speed Starter | Yes (Standard) | |||
| Automatic Exposure Control | Yes (Standard) | |||
| Automatic Programming | Yes, with easy programming on standard touch screen console | |||
| Power Output | 65kW, 80kW (50kW available upon request) | |||
| Overhead Tube Stand | ||||
| Longitudinal Travel | 131.2 inches to 235.22 inches (3358 mm to 6000 mm) |
|||
| Transverse Travel | 78.7 inches to 136 inches (2000 mm to 3450 mm) | |||
| Vertical Travel | 61 inches (1575 mm) | |||
| Focus - Ceiling Distance | 27.58 inches to 89.55 inches (726 mm to 2300 mm) | |||
| Maximum Longitudinal | 186.45 inches (4765 mm) | |||
| Maximum Transverse | 91.57 inches (2351.5 mm) | |||
| Tube Support Rotation | +90°, -90° | |||
| Column - Vertical Axis | ± 135° w/ detents every 45° | |||
| Column - Horizontal Axis | ± 180° w/ detents every 45° | |||
| X-Ray Tube | 300, 400, or 600 kHu | |||
| Elevating Table | ||||
| Fixed Bucky | Yes (standard) | |||
| Table Top (XM, XT, XA models only) |
Elevating, Four-Way Float w/ electromagnetic brakes Carbon Fiber X-ray Dose: (0.65 mm Al at 100 kVp) | |||
| Table Top Dimensions (L x W) |
87 x 34 inches (2209 x 920 mm) | |||
| Minimum/Maximum Elevating Distance | Min: 20.8 inches (520 mm) Max: 34 inches (920 mm) | |||
| Patient Loading Capacity | 660 pounds (300 kg) | |||
| Chest Stand | ||||
| Fixed Bucky | Yes (standard) | |||
| Vertical Travel (optional) | 60 inches (150 cm) | |||
| Minimum Floor Distance | 15.7 inches (40 cm) | |||
| Maximum Floor Distance | 75.8 inches (190 cm) | |||
| Motorized Tilting Angles (optional) | +90°, -20° | |||
| Rotation | 90° | |||
| Options | ||||
| Model Name | Elite XM | Elite XT | Elite XA | |
| Positioning Movement - Manual | Yes | Yes | Yes | |
| Positioning Movement - Auto Tracking | - | Yes | Yes | |
| Positioning Movement - Auto Positioning | - | - | Yes | |
| Electronic Tomography | - | - | Yes | |
| Table | 660 lbs | 660 lbs | 660 lbs | |
| Touch-Screen | No | Yes, Displays Patient Name, Study Selected, Adjustable Generator Parameters | Yes, Displays Patient Name, Study Selected, Adjustable Generator Parameters | |
| Digital Detectors | Please contact an authorized representative. | |||
| Manual Rotating Bucky | Chest Stand (optional), Table (optional) | |||
| Specifications are subject to change without notice. | ||||

|