IU-16
Electric interpolator unit includes power supply
|
Interpolator Board IU-16 |
| Input signals |
Canon encoder
A phase, B phase sine wave signal
|
standard voltage
1 Vp-p (no load, output impedance 110
ohm) |
| Canon encoder
Z phase signals |
Open corrector or Balanced Line
Driver |
| Output signals |
up / down pulse
signal |
Pulse width
: 70 ± 20 nsec ( can be changed to 30 ± 10 nsec
) |
| A, B phase signal |
Divided rectangle signal ( PCA+,
PCB+, PCA-, PCB- ), Differential Line Driver |
| Z phase signal |
Pulse width
( PCZ+, PCZ- ) : 330 ± 80 µm ( can be changed ) |
Output type
|
Differential
line drivers |
Input signals response frequency
|
500 kHz max. |
Division accuracy
|
One cycle of
the encoder output is "a", the interval of adjoining
pulse is a / 16 ( 1 ± 1 / 4 ) |
| Power supply |
voltage
|
AC 90 ~ 132
V, 50 ~ 60 Hz |
power consumption
|
18 W max. |
Dimensions
|
180 x 285 x
70 mm |
| Ambient conditions |
Operating Temperature
|
0 to 50 ºC |
| Storage Temperature |
- 20 to 70 ºC |
|
FEATURES
- Maximum frequencies of input signals
are IU-40 : 300kHz, IU-16 : 500kHz.
- A phase B phase square wave signal
output (PCA,PCB) and UP/DOWN pulse output function
are equipped.
- Differential line Driver output.
|
|
|
|
 |
 |